Guangzhou Maya Medical Equipment CO.,LTD.511442About UsRoom 102, First floor, No. 2 Building, Bohou Industrial Park, No. 773 Xingnan Avenue, Nancun Town, Panyu District,GuangzhouGuangzhou Maya Medical Equipment CO.,LTD.511442About UsRoom 102, First floor, No. 2 Building, Bohou Industrial Park, No. 773 Xingnan Avenue, Nancun Town, Panyu District,GuangzhouGuangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LTD.Guangzhou Maya Medical Equipment CO.,LT

High resolution color TFT 5-channel waveform display Multi-parameter Patient Monitor

High resolution color TFT 5-channel waveform display Multi-parameter Patient Monitor

Categories: Patient monitor
Model NO.: MY-C002C
  • Place of Origin:CN
  • Instrument classification:Class II
  • Brand Name:MAYA
  • Model Number:MY-C002C
  • Product name:Multi-parameter Patient Monitor
  • Input dynamic range:±0.4mVp~±5mVp
  • HR measuring range:20bpm~300bpm
  • HR measuring accuracy:±1% or ±2bpm, whichever is greater
  • Display:7 inches TFT color LCD with 800x480 pixel
  • Alarming:Audible & visual alarm
  • Communication:Serial/Ethernet
  • Rechargeable Li-ion battery:14.8V 2200mAh
  • Power supply:100-240VAC, 50/60Hz
  • Standard Configuration:ECG, RESP. SpO2, NIBP, TEMP, PR
Product Description

High resolution color TFT 5-channel waveform display Multi-parameter Patient Monitorpatient monitor-1.jpg

NIBP

TechniqueOscillometric
Measurement range:
Systolic:40~260mmHg(adult)
40~230mmHg(pediatric)
40~130mmHg(neonate)
Diastolic:20~200mmHg(adult)
20~160mmHg(pediatric)
20~100mmHg(neonate)
MAP:26~220mmHg(adult)
26~183mmHg(pediatric)
26~110mmHg(neonace)
Measurement accuracy:average deviation ≤±5mmHg
standard deviation ≤8mmHg
Measurement mode:manual,automatic

TEMP

Measuring range25.0℃~4S.0℃
Measuring accuracy±0.2℃
Responding time≤150s
Quick temp(optional)<20s(skin),<2s(ear)

SpO2

TransducerDual-wave length LED
SpO2 measuring range35%-100%
Low perfusion capability0.4%-5%
SpO2 measuring accuracyArms less than 3% for SpO2 range from 70% to 100%
Low periiision performance0.4%
PR measuring range30bpm-240bpm
PR measuring accuracy±2bpm or ±2%, whichever is greater

ECG

Input dynamic range±0.4mVp~±5mVp
HR measuring range20bpm~300bpm
HR measuring accuracy±1% or ±2bpm, whichever is greater
HR alarm delay time≤10s
Sensitiyity selectionx1/2 x1. x2, tolerance ≤55%
Sweeping speed12.5mm/s, 25mm/s. 50mm/s, tolerance ≤10%
ECG noise level≤30μVp-p
ECG input loop current≤0.1μA
Input impedance≥5MΩ
Common-mode rejection ratio≥89dB
Time constant

≥0.3s (Monitoring mode)

≥3.2s (Diagnostic mode)

Frequency response

0.5Hz~40Hz (Monitoring mode)

0.05Hz~75Hz (Diagnostic mode)

RESP

RR measuring range0rpm~120rpm
RR measuring accuracy±5% or ±2 rpm, whichever is greater

Others

Power supply100-240VAC, 50/60Hz
Rechargeable Li-ion battery14.8V 2200mAh
Display7 inches TFT color LCD with 800x480 pixel
AlarmingAudible & visual alarm
CommunicationSerial/Ethernet

Standard Configuration
ECG, RESP. SpO2, NIBP, TEMP, PR

Option
CO2 . Nellcor SpO2 .Trolley, Wall-mount. SunTech NIBP Central monitoring system, External printer

patient monitor-2.jpg




Send Message

*
*
* clear input
* clear input
* clear input
* clear input
Preview on Mobile
X
customer-service Customer Service
whatsapp WhatsApp
wechat WeChat
message Message
go top Top
WeChat Close
qr code
18925044116
 

Send Message

*
*
* clear input
* clear input
* clear input
* clear input